HPLC L-3000 Rigol
High Performance Liquid Chromatography(HPLC) L-3000
RIGOL L-3000 HPLC Systems were designed in accordance with UHPLC standard, with an outstanding operating pressure limit 9,000 psi, that’s the highest pressure range compare to similar HPLC system.
RIGOL LC systems own independent intellectual property rights, all of the key units/modules are of autonomous design and manufacturing.It can be widely used in the fields of pharmaceutical, biochemical, environmental, food safety, petrochemical engineering, agriculturaland etc.
Features
Flexible and Easy to use
Modular design, with excellent flexibility. Multi-channel liquid system, easy to switch the mobile phase
High Automated
Automatic analysis, reporting, system flushing and shutdown, make the work efficiency greatly improved
Excellent Gradient Performance
Due to the innovative gradient system design, excellent gradient response can be achieved in any cases
Lower Delay Volume
Lower system delay volume, faster and more accurate response to gradient changes
Patented Technologies
Strong R & D team and industry-leading technical strength, all products are self-developed, with a number of patented technologies
Multiple Detectors
Withthe control of RIGOLChromatographyDataSystems, L-3000LCSystem can be fitted with a variety of detectorsor combination
With Excellent High Quality Help Your Analysis Comprehensively
- Up to 9000 PSI operational pressure. Higer working pressure extends the dynamic range in the application of chromatographic analysis, and improves the durability and reliability of the entire system.
- Up to 2.5 AU linear range of the detector, allows accurate analysis for widely varying sample concentrations, either with high concentrated substance(s) or trace component(s).
- Up to100Hz data sampling rate,allows sharper peak(s) detection and enables ultra fast analysis.
- As low as 5×10-9 g/mL detection limit, creating higher sensitivity with lower noise floor.
- Proprietary automatic solvent-compressibility compensation and pulsation dampening technologies enable excellent analysis reproducibility.
- Patented propulsion technology and ultrafine NC processing provide excellent system durability.
- User-friendly HPLC workstation, complies with the FDA 21 CFR Part 11, GLP, GMP regulations.
Flow Rate Range | 0.001mL/ min – 10.000mL/ min |
Flow Rate Accuracy | ±0.5% (@1mL/ min, water) |
Max Pressure | up to 9,000 psi |
Volume of Sample Loop | 100μL (optional for 10, 20 and 100) |
Column Oven Temperature Accuracy | ±1 °C |